Datamax E-4203 Printer Manual
There's a 'Media Sensor' in the Datamax that is evidently having trouble seeing the labels. The sensor is inside of a horizontal bar above the labels and just behind the Printhead.
In no event shall Datamax-O’Neil be liable to the. Resident in the Printer is owned by Licensor or its. No part of this manual may be reproduced. Preview Datamax Printers E-Class E-4203 User's Manual Online and Download PDF Manuals & Instructions for FREE from Manualagent.com.
That bar is movable. Make sure that the vertical mark, usually white, is positioned over the label - best if it is the center of the label. Download Portable Firefox more. Also make sure that there is no label or ribbon material stuck in that area.
Hold 'Feed' button down for a few seconds after checking those two things to 'Re-calibrate' the sensor. Answered on Apr 17, 2014 81 views. Hope you found a resolution to your issue by now, but if not, there was a firmware update meant to address calibration issues. You can also do an empty calibration where you remove the media and hold the feed button until the platen roller turns, then load the media and do the quick calibration where you press and hold the feed button. I have also found that moving the media sensor towards the center of the media sometimes helps. You can also try moving the media sensor, do the Empty Calibration, then the Quick Calibration, tehn move the sensor back and do both calibrations again. Answered on Jun 30, 2010 986 views.
The Media Sensor is not seeing the labels or is not configured for these labels. Check Media Sensor position and settings. The Fixed Sensor models have a small window for the sensor at the bottom of the printer, about 3/8' to the right of the left side. If the printer has a movable sensor, the typical position is either 1' to the right of the left edge of the labels, or in the center of the labels.


Typical media sensor setting is 'Gap Mode'. Another common issue is that the sensor might have a piece of label or something stuck to it, covering the lens.
Finally, there is a possibility that the reflectivity threshold may need to be recalibrated (see below). This can be difficult, although there are instructions in the Operator's Manual.
If physical position/clear view of labels by sensor doesn't seem to be the issue, an easier way to deal with settings issues might be to Restore to Factory Defaults (see below). Datamax E-Class Auto Media Calibration Procedure: The 'Auto Media Calibration Procedure' allows the operator to automatically obtain the optimum (TOF Low and TOF Delta) values for a particular media. These values are useful for media that continues to have troubles after Media Sensor has been manually calibrated (usually preprinted media). Bagaimana Mencari Kawan Pdf Reader there. This operation feeds 10 inches of media using the current Media Sensor Calibration setting and calculates the TOF Delta and TOF Low values to be used.